A SOC 2 bridge letter, also called a gap letter, covers the time between the end of your last SOC 2 report period and today. It is written and signed by your management, not by the auditor, and states that there have been no material changes to the system or controls and no significant incidents since the report period ended, or describes any that occurred. Customers ask for one when your latest report period ended several months ago. Bridge letters are usually accepted for gaps of up to about three months; longer gaps raise questions.
Why bridge letters exist
A SOC 2 Type 2 report covers a fixed period, for example 1 January to 31 December. The report itself is usually issued some weeks after the period ends. A customer reviewing vendors in May sees a report whose coverage stopped months earlier, and needs some assurance about the months in between. The bridge letter is that assurance, given by the people who run the system.
What a bridge letter should contain
Keep it short and factual, on company letterhead, signed by a senior officer.
- Your company name and the service covered by the report.
- The period covered by the most recent SOC 2 report and the audit firm that issued it.
- The bridge period: from the day after the report period ended to the date of the letter.
- A statement that there have been no material changes to the system, controls or control environment during the bridge period, or a description of any changes.
- A statement that you are not aware of any significant security incidents or control failures affecting the service during the bridge period, or a description of any.
- The expected start and end of the next report period and when the next report is expected.
- Name, title, signature and date.
Who issues it
Management issues the bridge letter. The audit firm does not, because it has not tested the bridge period. That is why customers treat it as a reasonable but weaker form of assurance than the report itself, and why its accuracy matters: a bridge letter that hides a known incident or a major change is a serious misstatement to a customer.
What counts as a material change
There is no fixed definition, so use judgement and be transparent. Examples that usually deserve mention include a move to a new cloud provider or region, replacing the identity provider, major changes to the product architecture, a change of key security leadership, the loss of a critical subservice organisation, and any security incident that affected customer data or the service's availability commitments.
Disclosing a change is not a failure. Customers expect systems to evolve. They want to know about changes that affect the assurance they rely on.
How long a gap is acceptable
Practices vary by customer, but many accept bridge letters covering up to about three months. Beyond that, customers often ask why the next report is late, request additional evidence, or escalate the vendor review. A bridge letter covering most of a year is usually a sign that the audit cycle has slipped.
Planning periods so gaps stay short
The simplest way to manage bridge letters is to need few of them. Use twelve-month report periods that follow each other without gaps, and agree with your auditor a target issue date a few weeks after each period ends. If many customers review vendors at a particular time of year, consider aligning your period end so the report is fresh at that time.
Keep a bridge letter template ready, owned by the person who runs your SOC 2 programme, and review it whenever a material change occurs, not only when a customer asks.
A sample structure
A bridge letter can be four short paragraphs. The first identifies the company, the service and the most recent SOC 2 report, including its period and the issuing firm. The second states the bridge period and confirms there have been no material changes to the system or its controls during that time, or lists them. The third confirms management is not aware of any significant security incidents or control failures during the bridge period, or describes them. The fourth gives the dates of the current report period and when the next report is expected, followed by a signature. Keep the wording factual and avoid marketing language; the letter will be read by risk teams, not prospects.
Store each issued letter with the date and recipient, so you can show what was said to whom if questions arise later.
Related documents customers may ask for
Alongside the report and bridge letter, customers sometimes ask for your penetration test attestation, your security policies summary, or answers to a standard questionnaire. Our posts on SOC 2 Type 1 vs Type 2 and penetration testing before an enterprise deal cover those. Our SOC 2 service can manage the annual cycle for you.
Frequently asked questions
What is a SOC 2 bridge letter?
Does the auditor sign the bridge letter?
How long can a bridge letter cover?
What if there was an incident during the bridge period?
Keep your SOC 2 cycle gap-free
We plan continuous report periods and keep your bridge letter ready, so customer reviews never stall.